Fluxul de turbină
descrierea produsului

Folosiți mediul


Temperatură ambientală -20 ~ +55 ℃

Temperatura relativă 5% ~ 95%

Presiune atmosferică 86-106kpa


Temperatura fluidului este măsurată

Tip obișnuit -20 ~ +120 ℃

Tip rezistent la explozie -20 ~ 70 ℃

Turbine Flowmeter

Structura și dimensiunea conexiunii:

Construcție filetată

Turbine Flowmeter


Setarea parametrilor

Main Menu

Cipher

Option

Set value

Instruction

Parameter 




setting

10000

Language

Chinese/English

1. Preset selection

2. Default Chinese

Mailing address

0~254

1. Enter the device,communication address

2. This option is not available for battery power

3. Select current output product, this setting is invalid

4. Only selected communication products with 485 take effect

5. Default address 001

Baud rate

24004800960019200

1. 1. Preset selectionBaud rate of device communication

2. This option is not available on battery power

3. Select current output product, this setting is invalid

4. Only the communication product with 485 takes effect

5. Default 2400

Flow unit

m3/h, m3/m, m3/s,

L/h, L/m, L/s,

Kg/h, Kg/m, Kg/s

1. Preset selection

2. The default is m3/h

Range setting

0~59999

1. Input setting

2. Range units change as flow units are modified

3. The default value is 100

Damping time

1~16

1. Enter the Settings

2. The default value is 04

Small signal excision

0~100%

1. Input setting

2. If the input is greater than 100%, it is equal to 100%

3. Default 0

Instrument coefficient

1~9999999

1. Input setting

2. Correct the flow value

3. Default 3600

Set density

1~59999

1. Input setting

2. Modified fluid density

3. Default 1000Kg/ m3

Output mode

Pulse output/current output

1. Preset selection

2. Battery powered does not have this option

3. Select the product with 485 communication function, this setting function is invalid if set to current output, only pulse output can be selected

4. Default current output

Cumulative setting

0~999999999.999

1. Input setting

2. The default value is the actual total value of the system

Current zero correction

0~5.9999

1. Input setting

2. The default value is the factory revision value. Users are prohibited to modify it under special circumstances

Current full degree correction

0~5.9999

1. Input setting

2. The default value is the factory revision value. Users are prohibited to modify it under special circumstances


Compania noastră Turbine Flowmeter este cel mai bine vândut contor de flux, de asemenea, producem debitmetrul rece sau de căldură, contor de nivel sau instrumente și alte contoare populare, dacă aveți nevoie, vă rugăm să nu ezitați să ne contactați.

Acasă> Produse> Debitmetru> Fluxul de turbină> 4-20mA Curent Converter Turbine Flowmeter
Contactează-ne
Abonati-va
Urmează-ne

Copyright © 2024 Jiangsu Baichuang Instrument Group Co.,Ltd Toate drepturile rezervate.

Trimite o anchetă
*
*

Vă vom contacta imediat

Completați mai multe informații, astfel încât să poată lua legătura cu tine mai repede

Declarație de confidențialitate: Confidențialitatea dvs. este foarte importantă pentru noi. Compania noastră promite să nu vă dezvăluie informațiile personale pentru nicio expansiune cu permisiunile dvs. explicite.

Trimite